Technical parameters:
Items |
Unit |
Index |
Core No. |
|
2-12 |
14-24 |
Diameter/Height |
mm |
8.0/15.0 |
9.1/16.2 |
Unit weight |
Kg/km |
135 |
160 |
Max. Allowable tension |
N |
3500/1000 (short term/long term) |
Max. Allowable crush |
N/100mm |
1000/300 (short term/long term) |
Attenuation |
dB/km |
≤0.36dB/km@1310nm, ≤0.22dB/km@1550nm |
Minimum bend radius |
mm |
During installation 20D,During Service 10D |
Operating temperature |
℃ |
-40~+60 |
Application:
Used for core net, city local net and OAN and applied to aerial.
Product Characteristic:
1. The messenger wire together with OFC as a whole part. OFC installation can be completed at one time. Ease construction and less affected by environment, reducing installation cost.
2. It adopts stranded galvanize steel wire with high tensile strength, which can meet the requirement of existing telephone pole.
3. Loose tube filled with gel and wrapped longitudinal water blocking tap, ensuring good moisture protection and water blocking.
4. It makes the whole structure compact with thermal melting gluey drop coated on the loose tube surface. Precision control for over length ensures OFC with excellent performances of mechanical tensile strain and environment temperature.
It could ensure much better moisture resistance and improve side press resistance perform with corrugated longitudinal steel plastic tape wrapping cable core.